Configure logging
editConfigure logging
editThe logging
section of the filebeat.yml
config file contains options
for configuring the logging output.
The logging system can write logs to the syslog or rotate log files. If logging
is not explicitly configured the file output is used.
logging.level: info logging.to_files: true logging.files: path: /var/log/filebeat name: filebeat keepfiles: 7 permissions: 0644
In addition to setting logging options in the config file, you can modify the logging output configuration from the command line. See Command reference.
When Filebeat is running on a Linux system with systemd, it uses
by default the -e
command line option, that makes it write all the logging output
to stderr so it can be captured by journald. Other outputs are disabled. See
Filebeat and systemd to know more and learn how to change this.
Configuration options
editYou can specify the following options in the logging
section of the
filebeat.yml
config file:
logging.to_stderr
editWhen true, writes all logging output to standard error output. This is
equivalent to using the -e
command line option.
logging.to_syslog
editWhen true, writes all logging output to the syslog.
This option is not supported on Windows.
logging.to_eventlog
editWhen true, writes all logging output to the Windows Event Log.
logging.to_files
editWhen true, writes all logging output to files. The log files are automatically rotated when the log file size limit is reached.
Filebeat only creates a log file if there is logging output. For
example, if you set the log level
to error
and there are no
errors, there will be no log file in the directory specified for logs.
logging.level
editMinimum log level. One of debug
, info
, warning
, or error
. The default
log level is info
.
-
debug
-
Logs debug messages, including a detailed printout of all events
flushed. Also logs informational messages, warnings, errors, and
critical errors. When the log level is
debug
, you can specify a list ofselectors
to display debug messages for specific components. If no selectors are specified, the*
selector is used to display debug messages for all components. -
info
- Logs informational messages, including the number of events that are published. Also logs any warnings, errors, or critical errors.
-
warning
- Logs warnings, errors, and critical errors.
-
error
- Logs errors and critical errors.
logging.selectors
editThe list of debugging-only selector tags used by different Filebeat components.
Use *
to enable debug output for all components. Use publisher
to display
debug messages related to event publishing.
The list of available selectors may change between releases, so avoid creating tests that depend on specific selectors.
To see which selectors are available, run Filebeat in debug mode
(set logging.level: debug
in the configuration). The selector name appears
after the log level and is enclosed in brackets.
To configure multiple selectors, use the following YAML list syntax:
logging.selectors: [ harvester, input ]
To override selectors at the command line, use the -d
global flag (-d
also
sets the debug log level). For more information, see Command reference.
logging.metrics.enabled
editBy default, Filebeat periodically logs its internal metrics that have changed in the last period. For each metric that changed, the delta from the value at the beginning of the period is logged. Also, the total values for all non-zero internal metrics are logged on shutdown. Set this to false to disable this behavior. The default is true.
Here is an example log line:
2017-12-17T19:17:42.667-0500 INFO [metrics] log/log.go:110 Non-zero metrics in the last 30s: beat.info.uptime.ms=30004 beat.memstats.gc_next=5046416
Note that we currently offer no backwards compatible guarantees for the internal metrics and for this reason they are also not documented.
logging.metrics.period
editThe period after which to log the internal metrics. The default is 30s.
logging.metrics.namespaces
editA list of metrics namespaces to report in the logs. Defaults to [stats]
.
stats
contains general Beat metrics. dataset
may be present in some
Beats and contains module or input metrics.
logging.files.path
editThe directory that log files are written to. The default is the logs path. See the Directory layout section for details.
logging.files.name
editThe name of the file that logs are written to. The default is filebeat.
logging.files.rotateeverybytes
editThe maximum size of a log file. If the limit is reached, a new log file is generated. The default size limit is 10485760 (10 MB).
logging.files.keepfiles
editThe number of most recent rotated log files to keep on disk. Older files are
deleted during log rotation. The default value is 7. The keepfiles
options has
to be in the range of 2 to 1024 files.
logging.files.permissions
editThe permissions mask to apply when rotating log files. The default value is
0600. The permissions
option must be a valid Unix-style file permissions mask
expressed in octal notation. In Go, numbers in octal notation must start with
0.
The most permissive mask allowed is 0640. If a higher permissions mask is specified via this setting, it will be subject to an umask of 0027.
This option is not supported on Windows.
Examples:
- 0644: give read and write access to the file owner, and read access to all others.
- 0600: give read and write access to the file owner, and no access to all others.
- 0664: give read and write access to the file owner and members of the group associated with the file, as well as read access to all other users.
logging.files.interval
editEnable log file rotation on time intervals in addition to size-based rotation. Intervals must be at least 1s. Values of 1m, 1h, 24h, 7*24h, 30*24h, and 365*24h are boundary-aligned with minutes, hours, days, weeks, months, and years as reported by the local system clock. All other intervals are calculated from the unix epoch. Defaults to disabled.
logging.files.suffix
editWhen a log rotation happens it can either rename older files with
an incresing index if count
is configured. The other option is date
that appends the current date and time to the end of the filename.
When the log is rotated a new file is created and older files
remain untouched.
logging.files.rotateonstartup
editIf the log file already exists on startup, immediately rotate it and start writing to a new file instead of appending to the existing one. Defaults to true.
logging.json
editWhen true, logs messages in JSON format. The default is false.
Deprecated in 7.16.0.
logging.ecs
editWhen true, logs messages with minimal required Elastic Common Schema (ECS) information.
Deprecated in 7.16.0.
logging.files.redirect_stderr
[preview]
This functionality is in technical preview and may be changed or removed in a future release. Elastic will work to fix any issues, but features in technical preview are not subject to the support SLA of official GA features.
editWhen true, diagnostic messages printed to Filebeat’s standard error output
will also be logged to the log file. This can be helpful in situations were
Filebeat terminates unexpectedly because an error has been detected by
Go’s runtime but diagnostic information is not present in the log file.
This feature is only available when logging to files (logging.to_files
is true).
Disabled by default.
Logging format
editThe logging format is generally the same for each logging output. The one exception is with the syslog output where the timestamp is not included in the message because syslog adds its own timestamp.
Each log message consists of the following parts:
- Timestamp in ISO8601 format
- Level
- Logger name contained in brackets (Optional)
- File name and line number of the caller
- Message
- Structured data encoded in JSON (Optional)
Below are some samples:
2017-12-17T18:54:16.241-0500 INFO logp/core_test.go:13 unnamed global logger
2017-12-17T18:54:16.242-0500 INFO [example] logp/core_test.go:16 some message
2017-12-17T18:54:16.242-0500 INFO [example] logp/core_test.go:19 some message {"x": 1}