Syslog input plugin
editSyslog input plugin
edit- Plugin version: v3.4.1
- Released on: 2018-04-06
- Changelog
For other versions, see the Versioned plugin docs.
Getting Help
editFor questions about the plugin, open a topic in the Discuss forums. For bugs or feature requests, open an issue in Github. For the list of Elastic supported plugins, please consult the Elastic Support Matrix.
Description
editRead syslog messages as events over the network.
This input is a good choice if you already use syslog today. It is also a good choice if you want to receive logs from appliances and network devices where you cannot run your own log collector.
Of course, syslog is a very muddy term. By default, this input only
supports RFC3164
syslog with some small modifications. However, some
non-standard syslog formats can be read and parsed if a functional
grok_pattern
is provided. The date format is still only allowed to be
RFC3164
style or ISO8601
.
For more information see the RFC3164 page.
Note: This input will start listeners on both TCP and UDP.
Syslog Input Configuration Options
editThis plugin supports the following configuration options plus the Common Options described later.
Setting | Input type | Required |
---|---|---|
No |
||
No |
||
No |
||
No |
||
No |
||
No |
||
No |
||
No |
||
No |
||
No |
Also see Common Options for a list of options supported by all input plugins.
facility_labels
edit- Value type is array
-
Default value is
["kernel", "user-level", "mail", "system", "security/authorization", "syslogd", "line printer", "network news", "UUCP", "clock", "security/authorization", "FTP", "NTP", "log audit", "log alert", "clock", "local0", "local1", "local2", "local3", "local4", "local5", "local6", "local7"]
Labels for facility levels. These are defined in RFC3164.
grok_pattern
edit- Value type is string
-
Default value is
"<%{POSINT:priority}>%{SYSLOGLINE}"
The default value should read and properly parse syslog lines which are fully compliant with RFC3164.
You can override this value to parse non-standard lines with a valid grok
pattern which will parse the received lines. If the line is unable to
be parsed, the _grokparsefailure_sysloginput
tag will be added.
The grok pattern must provide a timestamp
field. If the timestamp
field is omitted, or is unable to be parsed as RFC3164
style or
ISO8601
, a _dateparsefailure
tag will be added.
locale
edit- Value type is string
- There is no default value for this setting.
Specify a locale to be used for date parsing using either IETF-BCP47 or POSIX language tag.
Simple examples are en
,en-US
for BCP47 or en_US
for POSIX.
If not specified, the platform default will be used.
The locale is mostly necessary to be set for parsing month names (pattern with MMM) and weekday names (pattern with EEE).
port
edit- Value type is number
-
Default value is
514
The port to listen on. Remember that ports less than 1024 (privileged ports) may require root to use.
proxy_protocol
edit- Value type is boolean
-
Default value is
false
Proxy protocol support, only v1 is supported at this time http://www.haproxy.org/download/1.5/doc/proxy-protocol.txt
severity_labels
edit- Value type is array
-
Default value is
["Emergency", "Alert", "Critical", "Error", "Warning", "Notice", "Informational", "Debug"]
Labels for severity levels. These are defined in RFC3164.
syslog_field
edit- Value type is string
-
Default value is
"message"
Codecs process the data before the rest of the data is parsed. Some codecs,
like CEF, put the syslog data into another field after pre-processing the
data. Use this option in conjunction with the grok_pattern
configuration
to allow the syslog input plugin to fully parse the syslog data in this case.
input { syslog { port => 12345 codec => cef syslog_field => "syslog" grok_pattern => "<%{POSINT:priority}>%{SYSLOGTIMESTAMP:timestamp} CUSTOM GROK HERE" } }
timezone
edit- Value type is string
- There is no default value for this setting.
Specify a time zone canonical ID to be used for date parsing.
The valid IDs are listed on the [Joda.org available time zones page](http://joda-time.sourceforge.net/timezones.html).
This is useful in case the time zone cannot be extracted from the value,
and is not the platform default.
If this is not specified the platform default will be used.
Canonical ID is good as it takes care of daylight saving time for you
For example, America/Los_Angeles
or Europe/France
are valid IDs.
Common Options
editThe following configuration options are supported by all input plugins:
Details
edit
codec
edit- Value type is codec
-
Default value is
"plain"
The codec used for input data. Input codecs are a convenient method for decoding your data before it enters the input, without needing a separate filter in your Logstash pipeline.
enable_metric
edit- Value type is boolean
-
Default value is
true
Disable or enable metric logging for this specific plugin instance by default we record all the metrics we can, but you can disable metrics collection for a specific plugin.
id
edit- Value type is string
- There is no default value for this setting.
Add a unique ID
to the plugin configuration. If no ID is specified, Logstash will generate one.
It is strongly recommended to set this ID in your configuration. This is particularly useful
when you have two or more plugins of the same type, for example, if you have 2 syslog inputs.
Adding a named ID in this case will help in monitoring Logstash when using the monitoring APIs.
input { syslog { id => "my_plugin_id" } }
Variable substitution in the id
field only supports environment variables
and does not support the use of values from the secret store.
tags
edit- Value type is array
- There is no default value for this setting.
Add any number of arbitrary tags to your event.
This can help with processing later.
type
edit- Value type is string
- There is no default value for this setting.
Add a type
field to all events handled by this input.
Types are used mainly for filter activation.
The type is stored as part of the event itself, so you can also use the type to search for it in Kibana.
If you try to set a type on an event that already has one (for example when you send an event from a shipper to an indexer) then a new input will not override the existing type. A type set at the shipper stays with that event for its life even when sent to another Logstash server.