Create a monitor status rule

edit

There are two types of monitor status rules:

  • Synthetics monitor status for use with Elastic Synthetics.
  • [8.15.0] Deprecated in 8.15.0. Uptime monitor status for use with the Uptime app.

    The Uptime app and the Uptime monitor status rule are deprecated as of version 8.15.0.

    If you are using the Uptime monitor status rule with the Uptime app, you should migrate the Uptime monitor and the Uptime monitor status rule to Elastic Synthetics and the Synthetics monitor rule.

    If you are using the Uptime monitor status rule with a monitor created with Elastic Synthetics, you should migrate the Uptime monitor status rule to the Synthetics monitor rule. Learn how in Migrate from the Uptime rule to the Synthetics rule.

Synthetics monitor status
edit

Within the Synthetics UI, create a Monitor Status rule to receive notifications based on errors and outages.

Filtersedit

The Filter by section controls the scope of the rule. The rule will only check monitors that match the filters defined in this section. In this example, the rule will only alert on browser monitors located in Asia/Pacific - Japan.

Filter by section of the Synthetics monitor status rule
Conditionsedit

Conditions for each rule will be applied to all monitors that match the filters in the Filter by section. You can choose the number of times the monitor has to be down relative to either a number of checks run or a time range in which checks were run, and the minimum number of locations the monitor must be down in.

Retests are included in the number of checks.

The Rule schedule defines how often to evaluate the condition. Note that checks are queued, and they run as close to the defined value as capacity allows. For example, if a check is scheduled to run every 2 minutes, but the check takes longer than 2 minutes to run, a check will not run until the previous check has finished.

You can also set Advanced options such as the number of consecutive runs that must meet the rule conditions before an alert occurs.

In this example, the conditions will be met any time a browser monitor is down 3 of the last 5 times the monitor ran across any locations that match the filter. These conditions will be evaluated every minute, and you will only receive an alert when the conditions are met three times consecutively.

Filters and conditions defining a Synthetics monitor status rule
Action typesedit

Extend your rules by connecting them to actions that use the following supported built-in integrations.

Some connector types are paid commercial features, while others are free. For a comparison of the Elastic subscription levels, go to the subscription page.

After you select a connector, you must set the action frequency. You can choose to create a summary of alerts on each check interval or on a custom interval. For example, send email notifications that summarize the new, ongoing, and recovered alerts each hour:

synthetic monitor action types summary

Alternatively, you can set the action frequency such that you choose how often the action runs (for example, at each check interval, only when the alert status changes, or at a custom action interval). In this case, you must also select the specific threshold condition that affects when actions run: the Synthetics monitor status changes or when it is Recovered (went from down to up).

synthetic monitor action types each alert

You can also further refine the conditions under which actions run by specifying that actions only run when they match a KQL query or when an alert occurs within a specific time frame:

  • If alert matches query: Enter a KQL query that defines field-value pairs or query conditions that must be met for notifications to send. The query only searches alert documents in the indices specified for the rule.
  • If alert is generated during timeframe: Set timeframe details. Notifications are only sent if alerts are generated within the timeframe you define.
synthetic monitor action types more options
Action variablesedit

Use the default notification message or customize it. You can add more context to the message by clicking the icon above the message text box and selecting from a list of available variables.

synthetic monitor action variables

The following variables are specific to this rule type. You an also specify variables common to all rules.

context.checkedAt
Timestamp of the monitor run.
context.hostName
Hostname of the location from which the check is performed.
context.lastErrorMessage
Monitor last error message.
context.locationId
Location id from which the check is performed.
context.locationName
Location name from which the check is performed.
context.locationNames
Location names from which the checks are performed.
context.message
A generated message summarizing the status of monitors currently down.
context.monitorId
ID of the monitor.
context.monitorName
Name of the monitor.
context.monitorTags
Tags associated with the monitor.
context.monitorType
Type (for example, HTTP/TCP) of the monitor.
context.monitorUrl
URL of the monitor.
context.reason
A concise description of the reason for the alert.
context.recoveryReason
A concise description of the reason for the recovery.
context.status
Monitor status (for example, "down").
context.viewInAppUrl
Open alert details and context in Synthetics app.
Uptime monitor status
edit

The Uptime app and the Uptime monitor status rule are deprecated as of version 8.15.0.

If you are using the Uptime monitor status rule with the Uptime app, you should migrate the Uptime monitor and the Uptime monitor status rule to Elastic Synthetics and the Synthetics monitor rule.

If you are using the Uptime monitor status rule with a monitor created with Elastic Synthetics, you should migrate the Uptime monitor status rule to the Synthetics monitor rule. Learn how in Migrate from the Uptime rule to the Synthetics rule.

Within the Uptime app, create a Monitor Status rule to receive notifications based on errors and outages.

  1. To access this page, go to ObservabilityUptime.
  2. At the top of the page, click Alerts and rulesCreate rule.
  3. Select Monitor status rule.

If you already have a query in the overview page search bar, it’s populated here.

Conditionsedit

You can specify the following thresholds for your rule.

Status check

Receive alerts when a monitor goes down a specified number of times within a time range (seconds, minutes, hours, or days).

Availability

Receive alerts when a monitor goes below a specified availability threshold within a time range (days, weeks, months, or years).

Let’s create a rule for any monitor that shows Down more than three times in 10 minutes.

This rule covers all the monitors you have running. You can use a query to specify specific monitors, and you can also have different conditions for each one.

Monitor status rule

The final step when creating a rule is to select one or more actions to take when the alert is triggered.

Action typesedit

You can extend your rules by connecting them to actions that use the following supported built-in integrations. Actions are Kibana services or integrations with third-party systems that run as background tasks on the Kibana server when rule conditions are met.

You can configure action types on the Settings page.

Uptime rule connectors

After you select a connector, you must set the action frequency. You can choose to create a summary of alerts on each check interval or on a custom interval. For example, send email notifications that summarize the new, ongoing, and recovered alerts each hour:

Action frequency summary of alerts

Alternatively, you can set the action frequency such that you choose how often the action runs (for example, at each check interval, only when the alert status changes, or at a custom action interval). In this case, you must also select the specific threshold condition that affects when actions run: Uptime Down Monitor or Recovered.

Action frequency for each alert
Action variablesedit

Use the default notification message or customize it. You can add more context to the message by clicking the icon above the message text box and selecting from a list of available variables.

Default notification message for monitor status rules with open "Add variable" popup listing available action variables
Alert recoveryedit

To receive a notification when the alert recovers, select Run when Recovered. Use the default notification message or customize it. You can add more context to the message by clicking the icon above the message text box and selecting from a list of available variables.

Default recovery message for monitor status rules with open "Add variable" popup listing available action variables
Migrate from the Uptime rule to the Synthetics rule
edit

If you are currently using the Uptime monitor status with a monitor created with Elastic Synthetics, you should migrate the Uptime monitor status rule to:

Uptime status check to Synthetics monitor ruleedit
Filtersedit

The KQL syntax that you used in the Uptime monitor status rule is also valid in the Filter by section of the Synthetics monitor status rule. The Synthetics monitor status rule also offers dropdowns for several categories for easy filtering. However, you can still use KQL syntax for these categories if you prefer.

Conditionsedit

If you are using the Uptime availability condition refer to Uptime availability check to Synthetics availability SLI.

If you’re using the Uptime status check condition, you can recreate similar effects using the following Synthetics monitor status rule condition equivalents:

Uptime Synthetics equivalent

Number of times the monitor is down

ANY MONITOR IS DOWN >= {number} times

Example: ANY MONITOR IS DOWN >= 5 times

IS DOWN {number} times

Example: IS DOWN 5 times

Timeframe

WITHIN last {number} {time range unit}

Example: WITHIN last 15 minutes

WITHIN THE LAST {number} {time range unit}

Example: WITHIN THE LAST 15 minutes

Actionsedit

The default messages for the Uptime monitor status rule and Synthetics monitor status rule are different, but you can recreate similar messages using Synthetics monitor status rule action variables.

Uptime availability check to Synthetics availability SLIedit

SLOs allow you to set clear, measurable targets for your service performance, based on factors like availability. The Synthetics availability SLI is a service-level indicator (SLI) based on the availability of your synthetic monitors.

Filtersedit

The KQL syntax that you used in the Uptime monitor status rule is also valid in the Query filter field of the Synthetics availability SLI.

Conditionsedit

Use the following Synthetics availability SLI fields to replace the Uptime monitor status rule’s availability conditions:

Uptime Synthetics equivalent

Number of checks that are down relative to all checks run

ANY MONITOR IS UP IN < {percent} of checks

Example: ANY MONITOR IS UP IN < 90% of checks

Target / SLO (%) field

Example: 90%

Timeframe

WITHIN THE LAST {number} {time range unit}

Example: WITHIN THE LAST 30 days

Time window and Duration fields

Example: Time window: Rolling, Duration: 30 days

Actionsedit

After creating a new SLO using the Synthetics availability SLI, you can use the SLO burn rate rule. For more information about configuring the rule, see Create an SLO burn rate rule.